Becton Dickinson

www.cytobid.com
 Model  Specs

FACScantm

·        Workstation: Macintosh G4 with OS9, CellQuesttm 3.5 software, new 22" flat screen display and color ink-jet printer. CellQuesttm software provides high-performance acquisition and analysis tools for plotting, gating, statistical analysis, and reporting.

·        Laser: 15mW 488 nm air-cooled argon.

·        Electronic doublet discrimination: Allows for the removal of artifacts from analysis by width and area measurments.

·        Fluorescence Sensitivity: <1000 FITC MESF

·        Scatter sensitivity: Enables the separation of fixed platelets from noise and optimized for resolving lymphocytes, monocytes and granulocytes.

·        Compensation: Between FL1,FL2; FL2,FL3 controlled by hardware.

·        Minimum cell size: 0.2 microns.

·        Maximum analysis rate: 20,000 cells/sec.

·        Sample flow rates:12 and 60 μL/min.

·        Power: 120 VAC +/- 10%, 50/60 Hz +/-2 Hz. Current: 20 amps maximum

·        Sensor module dimensions/weight: 30" w x 23.5" d x 20" h / 135 lbs.

1993 BD FACScan serial number 82799: This 3-color, 5-parameter, single laser flow cytometer is capable of immunophenotyping, absolute counting, residual white blood cell enumeration, stem cell analysis, DNA analysis, and isolation by the sorting option. Provides cellular and molecular analysis in such fields as genetics, immunology, microbiology, pathology, toxicology, pharmaceuticals, urology, nephrology, epidemiology, bioengineering, proteomics and plant pathology.

FACSorttm

·        Computer: Macintosh G4 with OS9, CellQuesttm 3.5 software, new 22" flat screen display and color ink-jet printer. CellQuesttm software provides high-performance acquisition and analysis tools for plotting, gating, statistical analysis, and reporting.

·        Laser: 15mW 488 nm air-cooled argon.

·        Electronic doublet discrimination: Allows for the removal of artifacts from analysis.

·        Fluorescence Sensitivity: <750 MESF

·        Coefficient of variation (CV): <3% full peak for propidium iodide–stained chicken erythrocyte nuclei.

·        Scatter resolution: Enables the separation of fixed platelets from noise and optimized for resolving lymphocytes, monocytes and granulocytes.

·        Minimum cell size: 0.2 microns

·        Maximum analysis rate: 20,000 cells/sec.

·        Power: 120 VAC +/- 10%, 50/60 Hz +/-2 Hz. Current: 20 amps maximum

·        Sensor module dimensions/weight: 36" w x 24" d x 20" h / 198 lbs..

 

Options:

·        Add FL-4 (4 color)

1993 BD FACSort Serial Number B0197: This 4-color, dual laser flow cytometer has similar electronics and fluidics to the FACSCaliburtm. Only the paneling has been extensively modified. The analyzer is capable of immunophenotyping, absolute counting, residual white blood cell enumeration, stem cell analysis and DNA analysis. Provides cellular and molecular analysis in such fields as genetics, immunology, microbiology, pathology, toxicology, pharmaceuticals, urology, nephrology, epidemiology, bioengineering, proteomics and plant pathology, Sorting available as a separately priced option.

FACSCaliburtm

·        Workstation: Macintosh G4 with OS9, CellQuest 3.5 software, new 22" flat screen display and color ink-jet printer. CellQuesttm software provides high-performance acquisition and analysis tools for plotting, gating, statistical analysis, and reporting. Can acquire up to 6 parameters and analyze 8 parameters (including time).

·        Lasers: 15mW 488 nm air-cooled argon with option of adding 635 nm red diode laser spatially separated for high sensitivity, minimal compensation, and maximum flexibility in fluorochrome selection.

·        Electronic doublet discrimination: Allows for the removal of artifacts from analysis by width and area measurements.

·        Fluorescence Sensitivity: <750 MESF

·        Coefficient of variation (CV): <3% full peak for propidium iodide–stained chicken erythrocyte nuclei.

·        Scatter resolution: Enables the separation of fixed platelets from noise and optimized for resolving lymphocytes, monocytes and granulocytes.

·        Compensation: Between FL1,FL2; FL2,FL3; FL3,FL4 controlled by hardware

·        Minimum cell size: 0.2 microns.

·        Maximum analysis rate: 20,000 cells/sec.

·        Sample flow rates:12, 35 and 60 μL/min.

·        Power: 120 VAC +/- 10%, 50/60 Hz +/-2 Hz. Current: 15 amps maximum

·        Sensor module dimensions/weight: 36" w x 24" d x 26.5" h (49" high with cover open)/ 240lbs.

 

 
2009 BD FACSCalibur serial number E97300363: This flow cytometer had only been used briefly at the recent winter Olympics in Vancouver, BC. It currently only has a 488 nm laser but bidders can elect to have the red laser installed with BD optical and electronic components. Sorting and Auto Loader options are also available. It is capable of providing immunophenotyping, absolute counting, residual white blood cell enumeration, stem cell analysis, DNA analysis, and isolation by the sorting option. Provides cellular and molecular analysis in such fields as genetics, immunology, microbiology, pathology, toxicology, pharmaceuticals, urology, nephrology, epidemiology, bioengineering, proteomics and plant pathology.

LSRtm

·        Workstation: Macintosh G4 with OS9, CellQuesttm 3.5 software, new 22" flat screen display and color ink-jet printer. CellQuesttm software provides high-performance acquisition and analysis tools for plotting, gating, statistical analysis, and reporting. Histogram analysis is provided by Modfittm LT (Verity Software House).

·        Lasers: Coherent 20 mW 488 nm air cooled argon, Kimmon 8 mW 325 nm HeCd and 17 mW 633 nm HeNe. Substitute lasers can be quoted separtely.

·        Electronic doublet discrimination: Allows for the removal of artifacts from analysis by width and area measurments.

·        Fluorescence Sensitivity: 200 fluoroscein MESF using Spherotech Rainbow RCP-30-5A beads.

·        Fluorescence Compensation: Provided by FloJotm analysis software (Tree Star, Inc.)

·        Maximum Analysis Rate: 20,000 cells/sec.

·        Sample flow rates:12, 35 and 60 μL/min.

·        Power: 120 VAC +/- 10%, 50/60 Hz +/-2 Hz. Current: 20 amps maximum

·        Sensor module dimensions/weight: 76" (193 cm) w x 34" (87 cm) d x 50" (127 cm) h / 525lbs (239 kg).

2001 BD LSR serial number 80148 This 6-color, 8-parameter, 3- laser flow cytometer is capable of immunophenotyping, absolute counting, residual white blood cell enumeration, stem cell analysis and DNA analysis. Provides cellular and molecular analysis in such fields as genetics, immunology, microbiology, pathology, toxicology, pharmaceuticals, urology, nephrology, epidemiology, bioengineering, proteomics and plant pathology.

FACSVantagetm DItm

·        Computer: HP X4000 (Intel/Windows) with 22" flat screen display and color printer. Supports both FCS 3.0 and 2.0 file formats. Software allows protocol definition and batch analysis. Multiple gating options. Can acquire up to 16 parameters and analyze 36 parameters (16 area, 16 height, 2 ratio, one width and on time)..

·        Lasers: 200 mW 488 nm solid state and 100 mW Coherent cube.

·        Electronic doublet discrimination: Allows for the removal of artifacts from analysis.

·        Fluorescence Sensitivity: <200 MESF using Spherotech Rainbow RCP-30-5A particles; <1000 fluorescein MESF using Bangs Quantum particles labeled with fluorescein.

·        Coefficient of variation (CV): <3% full peak for propidium iodide–stained chicken erythrocyte nuclei.

·        Sorting Speed: Up to 20,000 events/second utilizing a 70μ nozzle.

·       Nozzles tips: 50, 70 and 100μ.

·        Power: 120 VAC +/- 10%, 50/60 Hz. Current: 20 amps maximum

·        Sorter module dimensions/weight: Requires about 7ft x 7 ft. floor space. Approximately 700 lb.

 

BD FACSVantage DiVatm: This 6-color, 8-parameter, 2-laser stream-in-air sorting flow cytometer can be expanded to 3-lasers with 10 or more colors. Includes TurboSorttm, ACDU (96-well), AccuDroptm, 2-way and 4-way sorting. Currently Located at the seller's facility. Availability contingent upon FACSAriatm replacement. Shall be Sent to CytoBid at that time for refubising.

These flow cytometers will have the appearance and operation of like-new instruments.

All equipment is guaranteed to meet or exceed original factory performance.  Service contracts and financing are available.

You may contact our sales department for additional information and specifications on these products.