Beckman/Coulter Flow Cytometers 

 Model

 Specs

     Epics Elite

·         3-color (optional 4-color) fluorescence

·         Utilizes air-cooled 10mw HeNe, 15mw Ar, 10mw HeCd and/or water-cooled Ar UV lasers

·         Available light beams (µm): 15 x 16, 15 x 120 or 15 x 80 (optional)

·          Flow-cell is 250µm x 250µm with 76µm orifice

·        Detector range is 300µm to 800µm.

·         Detector Sensitivity is <1000 mol equiv FITC/particle

·         Minimum cell size is 0.2µm 

·        Maximum analysis rate is 20,000 cells/sec

·        Maximum sort rate is 7,000 cells/sec

·        Any combination of 8 single or dual parameter histograms, real-time or list mode, 2 oscilloscope traces, 1024 channel resolution (all channels), real-time video sort monitor.

·         80386/80387 25mhz plus microprocessor w/ 80188 cytometer CPU

·        8 MB memory, zero wait state, 80 MB hard disk, 3.5 floppy, optional 8 MB additional RAM, 800 MB optional.

·        VGA color CRT, PaintJet, Laser-Jet printers

·        Up to 4 lasers at a time, computer controlled fluidics, video sort setup & monitoring, biohazard containment, total instrument control by software, IBM PC compatible Prism multicolor system, time as a parameter, Q-prep and DNA-prep for sample preparation.

1999 Coulter Epics Elite ESP with Coulter Flow Center Computer, Nokia monitor, Coulter Z1 particle counter, Coulter DNA-Prep, Elite Autoclone, Multicycle DNA Windows software, air-cooled argon laser and HeNe laser.  As-is, where-is $53,000.  

1990 Coulter Elite with working air-cooled argon and HeNe lasers, as-is, whereis: $15,000

Epics Profile II

·        3-color fluorescence  

·    Air-cooled 488nm laser

·         14µ x 70µ elliptical light beam

·         Detector Range:  200nm-800nm

·         Flow-Cell Size:  250µ x 250µ BioSense

·        Max analysis rate:  >10000 cells/sec

·        Min Cell Size, um:  <0.5   

·          Digital oscilloscope with 2 Monitors and infrared activity screen, LCD of instrument status, multiple histograms with stats, 1024 channel resolution.  

·         Intel 80286 16-bit. 80287 64-bit coprocessor three 8085s

·         2.5 MB RAM, 32 KB histogram, 128 KB display, 20 MB Winchester, 3.5 floppy, optional 20 MB removable drive

·         Biohazard containment, multitasking operating system, clinical report forms, multiple amorphous bitmap gating.  Options include FlowNet, (Ethernet) to IBM PC compatibles; Power-Pak for 3-color and DNA doublet discrimination; 3 or 4 decade amplifier, IBM PC 386 and CytoLogic DNA Analysis and Easy-2 software for off-line analysis; Q-prep and DNA-Prep for sample preparation.

 

Please Inquire for Availability of Epics Profile IITM

Epics XL

·        3-color fluorescence with 4-color option

·    Air-cooled 488nm 15mw laser

·         10µ x 90µ light beam

·         Detector Range:  300nm-800nm

·         Flow-Cell Size:  250µ x 250µ BioSense

·        Max analysis rate:  >3300 cells/sec

·        Min Cell Size, um:  <0.5   

·         Color dot density; contour, isometric, tomogram, overlay, legend and projection plots.  PRISM displays; color precedence or color-blend gating; automatic Boolean logic gate creation; 32 gates per file, real-time statistics.

·         Intel Pentium processor and 4 network transputers for digital signal processing.

·         30 GB hard drive, 3.5" floppy, 40x IDE CD-ROM and SCSI 2 support, network card, 128 MB RAM, opt internal recordable CD, zip drive and JAZZ drive.

·         Signal-intensity display, biohazard-safe triple-fluid (sheath/cleanse/waste) system with automated functions and variable flow rate; auto setup; SYSTEM II software with acquisition, list mode, multigraph, reports and utilities.  Features FastSet and CellTracker. Opt tetraONE SYSTEM software automates 4-color acquisition and analysis.  Retic-ONE SYSTEM software for reticulocyte enumeration. XL-MCL incorporates automated multitube carousel loader--directly compatible with CellPrep, PrepPlus and TQ-Prep sample preparation systems for approx. 100 tube/hr. throughput plus integrated bar-code scanner for 3-way sample ID (carousel, tube, position and sample tube).

 

NOTE: Some specifications and options may vary with year and model

 

Dimensions: 20"h x 24"w x 22.5"d

Weight: 140 lb.

1999 Coulter XL, 3-color, never used.   Purchased as backup instrument to satisfy a contract.  4-color upgrade available through Beckman-Coulter.   $39,000 as-is, where-is.  Rebuild and warranty quoted separately.  

Epics XL-MCL

      The Coulter Epics XL-MCL has the same specifications as the XL except that it incorporates an automated multitube carousel loader--directly compatible with CellPrep, PrepPlus and TQ-Prep sample preparation systems for approx. 100 tube/hr. throughput plus integrated bar-code scanner for 3-way sample ID (carousel, tube, position and sample tube).

 

Analyzer dimensions: 20"h x 34.1"w x 22.5"d

Workstation dimenstions: 17"h x 9"w x 17"d

Weight: 187 lb.

 

Please Inquire for Availability of Epics XL-MCL

Epics ALTRA

 

Please Inquire for Availability of Epics ALTRA

Welcome to Spectron Corporation's Beckman/Coulter Flow Cytometers product page!

It is not possible to list all of the manufacturers and models we can provide here. Please contact us if you do not see the specific manufacturer or model you are interested in.

You may contact our sales department for additional information and specifications on these products.

This document maintained by spectroncorp.com.
Material Copyright © 1998 Spectron Corporation